home *** CD-ROM | disk | FTP | other *** search
/ HamCall (October 1991) / HamCall (Whitehall Publishing)(1991).bin / amateur / kenwood / svcbull / sb018.doc < prev    next >
Text File  |  1990-10-14  |  5KB  |  141 lines

  1.  
  2. SB-018
  3.  
  4. Service Notes on TR-7400A                             10-6-77
  5.  
  6. PLL and LED Display
  7.  
  8. 1.   No transmit or PLL unlock light on:  R-27 shorted to shield at D-1 on
  9. VCO Unit (X50-1370-10).
  10.  
  11. 2.   LED display changes when pushing on LED boards:  Remove LED display
  12. boards on display mother board.  Trim all wires as close to the circuit
  13. board as possible.  Insulate the foil side of the board with thin plastic
  14. and reinstall.
  15.  
  16. 3.   PLL unlock light on:  Check for 9 volts at 9V terminal on VCO Unit
  17. (X50-1370-10).  Check Q10 (2SC496) and zener D5 (WZ-061) on this board.
  18.  
  19. 4.   PLL unlock light on and no signal at PI terminal on PD Unit (X50-1380-
  20. 10):  Check for open ferri-inductor L1 in emitter lead of Q1 on VCO Unit
  21. (X50-1370-10).
  22.  
  23. 5.   PLL unlock light on and no signal at pin 3 of IC4 on PD Unit (X50-
  24. 1380-10):  Check for proper divide down signals on IC10, 5, 6, 7, 8.
  25.  
  26. 6.   Digits in display are intermittent or some segments are not properly
  27. lit:  Reseat the connectors on the Display Unit (X54-1210-10).  (Push them
  28. with a small screw driver.)
  29.  
  30. 7.   PLL unlock light stays on when unit is first turned on or cold:
  31. Change R4 on the PD Unit (X50-1380-10) from 470 ohms to 47 ohms.
  32.  
  33. 8.   PLL unlock light is on for about 2 minutes when the unit is first
  34. turned on and the inputs to IC4 on the PD Unit are ok, but there is no
  35. output:  Defective IC-4.
  36.  
  37. 9.   LED display changes when slightly turning or pressing down on channel
  38. select knobs:  Check for loose solder connections on the circuit board
  39. under the BCD switches.  (ON bottom of unit.)
  40.  
  41. 10.  One segement of one LED is dim:  LED may be defective or the resistor
  42. network may not be properly soldered.
  43.  
  44. 11.  Speaker howl at high volume levels:  Reseal the VCO coil (inside small
  45. shield box) on the VCO unit (X50-1370-10).  use Q dope or a small amount of
  46. Epoxy glue.  The VCO must be retuned after the glue dries.
  47.  
  48. 12.  -600 KHz offset does not work:  Check for open ferri-inductor L1 on PD
  49. unit (X50-1380-10)
  50.  
  51. 13.  LR frequency cannot be adjusted to meet specifications:  Check for
  52. proper frequency at TP1 on the PD unit.  It should be 2.56000MHz.  (Must
  53. use a 33 pf capacitor when counting this frequency)
  54.  
  55. RECEIVER
  56.  
  57. 1.   Receiver sensitivity down 30db:  Check voltage at the drain of Q1
  58. (3SK41L) on the RX Unit (X55-1150-10).  It should be 7 volts.  If it is
  59. "0vdc", check for shorted feet-thru capacitor in the helical resonator.
  60. It may be necessary to replace the helical resonator.
  61.  
  62. 2.   No receive:  Check C9 voltage.  Q27 (CSC496) on RX unit may be
  63. defective.
  64.  
  65. 3.   No receive and no C9 voltage:  Check Q28 (CSC496) and zener D16
  66. (WZ090) on the RX unit.
  67.  
  68. 4.   Intermittent receiver audio:  Check for shorted terminals on the
  69. volume and squelch controls.
  70.  
  71. 5.   Receiver sensitivity down:  Check for proper level of LR signal.  If
  72. down, check diode D-6 (1S2588) on the VCO Unit (X50-1370-10).
  73.  
  74. 6.   Receiver audio jumping up and down:  Check C59 and C62 on RX unit.
  75.  
  76. 7.   No receive or low sensitivity:  Check for proper output of 10.245MHz
  77. oscillator.  The 10. 245 MHz crystal may be defective.
  78.  
  79. 8.   Intermittent receive:  Check discriminator colil L14 on RX Unit. It
  80. may be open.
  81.  
  82. 9.   Meter lamp out:  Replace small lamp (B30-9996-05) as follows:
  83.  
  84.      1.  Remove meter
  85.      2.  Remove wires
  86.      3.  Remove small circuit board
  87.      4.  Replace lamp
  88.      5.  Reassemble
  89.  
  90.  
  91. TRANSMITTER
  92.  
  93. 1.   No meter indication but output power OK:  Check for broken wire at
  94. terminal SM1 on the RX Unit.
  95.  
  96. 2.   Transmitter intermittent when keyed rapidly:  Defective D3 (MI402) on
  97. PA unit (X45-1090-10).
  98.  
  99. 3.   Position of L2 in PA unit:  The proper position of this coil is
  100. directly on the collector tabs of Q2 (2N6083).  This applies to 45XXXX
  101. serial numbers only.
  102.  
  103. 4.   Background noise on transmit:  Reverse coil L1 on the TX unit (X56-
  104. 1230-10).
  105.  
  106. 5.   RF meter works when first key transmitter an then fails:  Check for
  107. pinched RF sens wire at coil L7 in PA unit.  Widen this coil if necessary.
  108.  
  109. 6.   Transmitter off frequency and receiver on frequency:  Adjust coil L3
  110. on TX Unit for correct frequency.
  111.  
  112. 7.   No RF output:  Diode D3 (MI402) in PA unit shorted or improperly
  113. soldered.  If this diode is replaced, keep the leads as short as possible
  114. an build up solder on the foil side of the board.
  115.  
  116. 8.   Low output power:  Loose connection at TC3 in PA Unit.
  117.  
  118. 9.   No RF output and receiver sensitivity dow 30db:  Diode D2 (MI301) on
  119. the PA Unit may be defective.  Also check D3 (MI402) on this board.  Q1
  120. (3SK41L) on the RX unit may also be defective.
  121.  
  122. 10.   Intermittent or no transmit:  Check for loose connection at Q15
  123. (2SC908) on the TX Unit.  Also check the heat sink for this transistor.
  124.  
  125. 11.  No RF output but drive to PA Unit is OK:  Check for proper SB voltage.
  126. It should be 11 to 12 vdc when transmitteing into a 50 ohm load.  If it is
  127. 0vdc check Q10 (2SC496) on the TX Unit.
  128.  
  129. 12.  No Modulation:  Capacitor C4 (0.1 ufd tantalum) on TX unit may be
  130. open.
  131.  
  132. 13.  No modulation:  Check for pinched pins at microphone jack.
  133.  
  134. 14.  No RF output on one band:  Check for proper alignment of
  135. potentiometers VR61, 62, and 63.
  136.  
  137. 15.  No RF output:  L4 not soldered to base of Q4 (2SC458B) in PA Unit.
  138.  
  139. (c) 10677TKC
  140.  